    Brand Name : ANGES
    Model Number : 12hp
    Payment Terms : L/C, T/T
    Delivery Time : 30 days
    • Product Details
    • Company Profile

    12HP Air Cooled Scroll Chiller for Industrial Process and BOPP Film Lamination Line

    Technical Parameters of Industrial Air-Cooled Chiller ACK-12


    Item


    Model

    ACK-12
    nominal cooling capacitykcal/h30014
    kw36.6
    input powerkw11.72
    power supply3PH-415V-50HZ
    refrigeranttypeR22
    type of controlExpansive valve
    compressortypehermetic scroll
    power(kw)9.3
    condensertypefinned copper tube + low noise outer rotor fan
    power(kw)0.92
    cooling air flow(m3/h)12000
    evaporatortypeShell and tube
    chilled fluid flow(m3/h)6.31
    volume(L)85
    Inlet/outlet pipe caliber(inch)2
    pumppower(kw)1.5
    flow (m3/h)12.5
    lift(m)20

    Safety

    protection

    compressor over temperature protection, over load protection, high and low pressure protection, flow switch protection, reversed and lacking phase protection, anti-freezing protection, fusible protection.
    weightkg550
    dimensionmm1530*780*1630

    Note: 1. Nominal cooling capacity is according to:

    Inlet chilled fluid temperature: 17℃; Outlet chilled fluid temperature: 12℃

    Inlet cooling air temperature: 30℃; Outlet cooling air temperature: 35℃

    2. Working range:

    The temperature range of chilled fluid is from 5℃ to 35℃;

    Temperature difference between inlet and outlet chilled fluid is from 3℃ to 8℃.

    It is better to use the chiller while the ambient temperature at or below 35℃.

    We reserve the right to modify the above dimensions or parameters without further notice.


    Configuration table for ANGES industrial Chiller

    PartsBrandRemark
    CompressorPanasonicJapan
    EvaporatorANGESChina
    CondenserANGESChina
    Expansion valveEmersonUSA
    Drying FilterDanfossDenmark
    Controller PCBPunpChina
    Electric ComponentsSchneiderFrance
    Pressure ControllerFenshengChina
    Oil Pressure GaugeJIUNAIChina
    PumpCNPChina
    FanMAERChina

    Quality 12HP Air Cooled Scroll Chiller for Industrial Process and BOPP Film Lamination Line for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Anges Machinery Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)